EasyManua.ls Logo

Precor EFX 5.17i - Page 62

Precor EFX 5.17i
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.17i Ellipitical Fitness Crosstrainer
Page 62
6. Position the magnet assembly at its mounting position so that the eddy current disk is
centered between the magnet poles.
7. Replace and hand tighten the magnet assembly mounting bolts. Torque the magnet
assembly mounting bolts to 43 in/lbs.
8. Reconnect the magnet cable to the magnet assembly.
9. Re-install the left and right cover sections as described in Procedure 7.1, then check the
operation of the EFX as described in Section Four.
10. Disconnect the magnet cable from the lower PCA. See Diagram 6.6.
11. Remove the bolts that fasten the eddy current magnet to its frame mounting. See Diagram
7.16.
Diagram 7.16 - Eddy Current Magnet (serial code AMPF)
12. Set the replacement eddy current magnet in its mounting position and fasten it with the
hardware removed in step 11. Torque the eddy current mounting bolts to 47 inch pounds.
13. Connect the magnet cable to the lower PCA.
14. Re-install the left and right cover sections as described in Procedure 7.1, then check the
operation of the EFX as described in Section Four.
Eddy Current
Magnet
Magnet
Cable
Mounting
Bolt