EasyManua.ls Logo

Precor EFX 5.17i - Procedure 7.13 - Replacing an Eddy Current Magnet Assembly

Precor EFX 5.17i
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.17i Elliptical Fitness Crosstrainer
Page 61
Procedure 7.13 - Replacing an Eddy Current Magnet
Assembly
Procedure
1. Set the on/off switch in the “off” position, then unplug the power cord from the wall outlet.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
2. Remove the left and right cover sections as described in Procedure 7.1.
3. For serial code AMPF, skip to step 10. For serial code SB, continue with step 4.
4. Disconnect the magnet cable from the magnet assembly. See Diagram 7.15.
5. Remove the bolts that secure the magnet assembly to the drive unit. Remove the magnet
from the drive unit.
Diagram 7.15 - Eddy Current Magnet (Serial code SB)
Mounting Bolts
Eddy Current
Magnet
Eddy Current
Disk
Magnet Cable