7. Set the on/off switch in the “off” position. Do not exit the diagnostic program in the normal
manner. Exiting the diagnostic program may cause the lift to self center and invalidate the lift
calibration just performed.
8. Raise the ramp assembly to a convenient height and slide the lift yoke into the ramp
assembly. Hand tighten the lift yoke mounting bolts and then torque them to 240 inch
pounds (20 foot pounds).
9. Set the on/off switch in the “on” position. Thoroughly test all lift functions.
10. Set the on/off switch in the “off” position, replace the front cover per Procedure 7.21.