COMMERCIAL PRODUCTS DIVISION
Press Enter once again and the Error Log appears. The EFX stores the last ten
errors that have been detected. Press any or key to view the error codes.
Note: If the EFX has no errors stored in memory, a “– – –” appears on the display.
To view the odometer reading at the time the error was detected and the hours of use
at the time the error occurred, press the Select key while the error code is being
displayed. The Select key acts as a toggle between the associated information.
To clear (delete) the error log, press Quick Start for at least four seconds while
viewing the list. Prompts appear on the display and confirm (OK) that the error
messages have been deleted (“cleared”) from memory.
Important: You cannot retrieve the error log once you have deleted it.
USING CSAFE STANDARD EQUIPMENT
The EFX is fully compatible with CSAFE protocols. Once the unit is connected to
a CSAFE master device and the user maintains a stride rate above 40 strides per
minute, he or she is prompted to enter an identification number (user ID).
Note: If the optional battery recharger is plugged into the EFX and connected to
an appropriate power source, then no pedaling is necessary for user ID entry.
Five zeros appear on the display. The left zero indicates that it is awaiting input.
The following table provides information about the keypad functions:
User ID Entry: Program Keys
or moves the blinking LED from field to field.
Enter submits the displayed user ID. Note that if the five zeros
are being displayed when the user presses Enter, the user
ID entry is bypassed and the Course prompt appears.
Reset resets the display to the Precor banner.
A message indicates when the user ID is accepted by the CSAFE master device.
Then, the course prompt is displayed. See
Quick Steps to Working Out
on page 39.
Note: If the user’s stride rate drops below 40 strides per minute while using the
CSAFE device connection, a prompt PEDAL FASTER appears. If the stride rate
remains below the 40 strides per minute threshold for the next twenty seconds,
the CSAFE connection is terminated. The word RESETTING appears on the
display while the EFX disconnects from the CSAFE device.
To review information about CSAFE specifications, visit the web site at:
www.fitlinxx.com/csafe
Note: The EFX supports the CSAFE master device per the specifications found
at the web site. However, exceptions do exist. If you have questions or need
technical support, refer to
Obtaining Service
on page 5.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor EFX524 and is the answer not in the manual?

Precor EFX524 Specifications

Power IconPower
powerSelf-powered
battery rechargerseparate purchase option
Electronic Specifications IconElectronic Specifications
incline1 to 20 degrees
resistance levels1 through 20
display readoutsCalories, Heart Rate, Smart Rate
Weight and Dimensions IconWeight and Dimensions
length79 inches (201 cm)
width32 inches (81 cm)
height63 inches (160 cm)
weight183 lbs. (82 kg)