Page 19
Description Replace Cost
Sediment Filter
 Part# 104017 6 Months $ 3.50
Carbon Filter
 Part# 101009 6 Months $10.50
Depending upon incoming feed water conditions replacement time
frame may vary.
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specied in NSF/ANSI 58. This
system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations of 0.30 mg/L or
less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free
chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined
chlorine) is not sufcient to ensure complete conversion of trivalent arsenic to pentavalent arsenic, Please see the Arsenic Facts section of the Performance Data
Sheet for further information.
Avg. In. Avg. Eff. % Reduction pH Pressure Max Eff. Inf. challenge Max Allowable
(mg/L) (mg/L) mg/L concentration concentration
mg/L mg/L
Arsenic (Pentavalent) 334.62 ug/L 5.039 ug/L 98.4% 50psi 19 ug/L 0.30±10% 0.010 mg/L
Barium Reduction 10.2 0.13 98.7% 7.24 50psi 0.27 10.0±10% 2.0
Cadmium Reduction 0.031 0.0001 99.7% 7.49 50psi 0.0009 0.03±10% 0005
Chromium (Hexavalent) 0.30 0.006 98.0% 7.24 50psi 0.013 0.03±10% 0.1
Chromium (Trivalent) 0.30 0.003 99.0% 7.24 50psi 0.008 0.03±10% 0.1
Copper Reduction 3.0 0.04 98.7% 7.64 50psi 0.06 3.0±10% 1.3
Cysts 222,077#/ml 10 #/ml 99.99% 50psi 58 minimum 50,000/mL N/A
Fluoride Reduction 8.0 0.33 95.9% 7.49 50psi 0.47 8.0±10% 1.5
Lead Reduction 0.15 0.004 97.3% 7.49 50psi 0.008 0.15±10% 0.0107
Perchlorate 0.10 0.003 96.5% 7.39 50 psi 0.005 mg/L 0.10±10% 0.006
Radium 226/228 25pCi/L 5pCi/L 80.0% 7.24 50psi 5pCi/L 25pCiL±10% 5pCiL
Selenium 0.10 <0.001 99.0% 50psi <0.001 0.10±10% 0.05
TDS 765 24 96% 7.84 50psi 39.0 750±40mg/L 187
Turbidity 81 NTU 0.15 NTU 99.8% 50psi 0.28 NTU 11±1 NTU 0.5 NTU
*Refer to the VOC Performance Data Sheet for the complete list of VOC’s.
Recovery - 16.0% Daily Production Rate - 9.56 GPD Efciency - 9.58%
Depending on water chemistry, water temperature, and water pressure Watts Premier’s R.O. Systems production and performance will vary.
Efciency rating means the percentage of the inuent water to the system that is available to the user as reverse osmosis treated water under
operating conditions that approximate typical daily usage. Recovery rating means the percentage of the inuent water to the membrane portion of
the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage
tank is bypassed. There is an average of 4 gallons of reject water for every 1 gallon of product water produced.
REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY
INFORMATION.
Phone: (480) 675-7995 Fax: (623) 866-5666 Email: wpmail@watts.com
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that
is microbiologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certied for cyst reduction may be used on
disinfected water that may contain lterable cysts.
2. Operating Temperature: Maximum: 100°F (40.5°C) Minimum: 40° (4.4°)
3. Operating Water Pressure: Maximum: 100 psi (7.0kg/cm2) Minimum: 40 psi (2.8kg/cm2)
4. pH 2 to 11
5. Maximum iron present in incoming feed water supply must be less than 0.2 ppm.
6. Hardness of more than 10 grains per gallon (170 ppm) may reduce RO membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
Performance Data Sheet
WP-4v
Watts Premier Inc.
8716 W Ludlow Drive Sutie #1
Peoria, AZ 85381 85027 USA
Description Replace Cost
Stage 4 - VOC Block Filter
 Part# 101013 12 Months $24.95
(600 Gallons)
RO Membrane
 35 GPD Part# 110016 2 to 5 Years $74.95