Automatic Relock Memory 80
(Factory Default: Enabled)
Disabling the Automatic Relock function prevents the ELC
relay output from deactivating 1 second after the door is
opened. This function is only valid when the DOOR input is
being used.
To disable the Automatic Relock function…
To enable the Automatic Relock function…
EGRESS Switch Type Memory 81
(Factory Default: Normally Open Level Triggered)
Either a normally open or normally closed EGRESS switch
setting may be selected.
To set the EGRESS switch input to N.O. level triggered…
To set the EGRESS switch input to N.C. level triggered…
To set the EGRESS switch input to N.O. edge triggered…
To set the EGRESS switch input to N.C. edge triggered…
When level triggered is selected the door will remain
unlocked whilst the egress is activated (button held on), once
the input is released normal ELC the timing will start.
When edge triggered is selected the door will unlock only for
the time set for ELC regardless of how long the egress input
is active for (button held on).