16
Door Open Too Long Timer Memory 85
(Factory Default: 60 seconds)
The time allowed for the door to be open before a DOTL
alarm is generated can be set from 1 to 9999 seconds. A
time of zero seconds will disable this function.
To change the DOTL time…
“the time in seconds”
Note that time of 0 seconds will disable the DOTL function.
Door Forced Open Detection Memory 86
(Factory Default: Enabled)
Disabling the Door Forced Open function prevents the DOTL
output from activating (contacts closing) when the door is
opened without a valid code or EGRESS switch having been
used.
To disable Door Forced Open Detection…
To enable Door Forced Open Detection…
One Minute Lockout Memory 87
(Factory Default: Disabled)
Enabling the 1 minute lockout function means that the system
will not accept any codes for 1 minute after 5 successive
invalid codes have been entered.
To disable the one minute lockout…
To enable the one minute lockout…
