2
CHANGES FROM SERIES 2
1. The PAC1 now supports 600 user codes.
2. Egress input can now be programmed as edge triggered
(momentary only) so that keeping the Egress input
triggered will not keep the door open permanently.
3. User code programming has been simplified (refer to the
supplied User Code Programming Manual).
4. Bulk adding of users is now supported.
5. Can be set to Series 2 compatible mode for use with
existing PACDL installations.
6. Two Codes Mode is now called High Security Mode.
SPECIFICATIONS
Voltage:
(absolute min-max)
1
11-30 Volts D.C.
14-28 Volts A.C.
Current:
120 mA D.C. max.
160 mA A.C. max.
ELC contacts:
(Electric Latch Control)
30 Volt, 5 Amp A.C./D.C. SPST.
Programmable as N.O. or N.C.
DOTL contacts:
(Door Open Too Long)
30 Volt, 1 Amp A.C./D.C. SPST.
Operating Temperature:
0C to 70C.
Size:
104mm x 72mm x 27mm.
Weight:
150gms.
1
Operating the unit at a voltage outside the specified range
may cause intermittent operation or result in damage to
the unit.