664Y3300
10800036: Address of the interface “0”
= 7
= 6
= 5
= 4
= 3
= 2
= 1
= 0
INSTALLATIoN
initial
Description
Maximum temperature set point for the domestic hot water.
The actual temperature set point is given from the Room Unit.
00: Domestic hot water “OFF”
01: Domestic hot water “ON”
00: Heating mode “OFF”
01: Heating mode “ON”
Temperature set point for the water in the heating circuit
(adjustable from 30 to 90°C).
Minimum temperature for the water in the heating circuit
(adjustable from 15 to 60°C).
Increase of the primary temperature set point to generate hot water
12: if there is a tank with an NTC sensor
13: if there is a tank with a thermostat
Bus A
Bus B
456 123 12345678910111213