EN 22
ENGLISHFRANCAISNEDERLANDSESpAñoLITALIANoDEuTSCH
664Y3300
INSTALLATIoN

This is a simple way of controlling two heating circuits (radiators
or floor heating).
These circuits may be set differently according to weather
conditions.
This configuration is ideal for a basic system of floor heating
with supplementary heating provided by radiators.
The floor circuit runs continuously according to a first heating
curve, while the radiator circuit follows a second heating curve,
with a booster function if needed.
RAM
prestige
MCBA
SQK
NTC12K
AF120
AM3-11
ACV 22
CONFIGURATION 3:
Installing two heating circuits and, optionally, a domestic hot water tank with regulation by a room
thermostat and an AM3-11 module.