The power supply of the modules in the cabinet is connected to a circuit breaker that removes
the power if overloading occurs.
The hot parts of the dosage valves are protected by a transparent, L-shaped plastic sheet.
Shielding on a dosage valve
Install and use the equipment in accordance with the instructions in the manual to ensure that
the safeguards function correctly.
Never bridge or remove the safeguards: this may lead to a serious accident.
Residual risks
The following risks could not be excluded in the design:
If the unit is altered or is used in such a way that it becomes contrary to the instructions in this
manual, unforeseen risks may occur.
If the pump switch is set to automatic, the process computer can start the pump. Therefore, set
the switch to off during maintenance when the process computer must remain on.
Because the unit is usually connected to other external electrical equipment the unit has not
been fitted with an emergency stop. The installer must install a separate emergency button near
the unit which can be used to switch off the entire installation.
9NutriJet - user - 00.002