MAINTENANCE AND TROUBLESHOOTING
Inspect and tighten all parts of the exercise bike regu-
larly. Replace any worn parts immediately.
To clean the exercise bike, use a damp cloth and a
small amount of mild soap. IMPORTANT: To avoid
damage to the console, keep liquids away from
the console and keep the console out of direct
sunlight.
CONSOLE TROUBLESHOOTING
Most console problems are the result of low batter-
ies. To replace the batteries, see assembly step 14 on
page 11.
If the console does not display your heart rate when
you use the handgrip heart rate monitor, see step 5 on
page 16.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed
switch, you must first
raise the Shield Cover
(12). Using a flat screw-
driver, release the tabs
on the Shield Cover,
and then lift the Shield
Cover away from the
frame.
Next, locate the Reed Switch (46). Loosen, but do not
remove, the M4 x 19mm Screw (18).
Next, rotate the Pulley (43) until a Magnet (44) is
aligned with the Reed Switch (46). Slide the Reed
Switch slightly toward or away from the Magnet. Then,
retighten the M4 x 19mm Screw (18).
Rotate the Pulley (43) for a moment. Repeat these
actions until the console displays correct feedback.
When the reed switch is correctly adjusted, reattach
the shield cover.