MAINTENANCE
Regular maintenance is important for optimal per-
formance and to reduce wear. Inspect and properly
tighten all parts each time the elliptical is used.
Replace any worn parts immediately.
To c l ean the e llip tica l, u s e a damp clot h an d a s mall
amount of mild dish soap. IMPORTANT: Keep liquids
away from the console and keep the console out of
direct sunlight. During storage, remove the batter-
ies from the console.
CONSOLE TROUBLESHOOTING
Most console problems are the result of low batteries.
To replace the batteries, see assembly 7 on
page 10.
If the handgrip heart rate monitor does not function
properly, see step 5 on page 20.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
Using a standard
screwdriver, remove
the Top Shield (41).
Note: For clarity, the right pedal disc is not shown in the
drawing below.
Locate the Reed Switch (53). Loosen, but do not
remove, the M4 x 16mm Screw (52).
Next, rotate the Pulley (61) until a Magnet (58) is
aligned with the Reed Switch (53). Slide the Reed
Switch slightly toward or away from the Magnet. Then,
retighten the M4 x 16mm Screw (52). Rotate the Pulley
for a moment.
Repeat these actions until the console displays correct
feedback.
When the reed switch is correctly adjusted, reattach
the top shield.
41
52
61
53
58
MAINTENANCE AND TROUBLESHOOTING

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pro-Form 225 CSE and is the answer not in the manual?

Pro-Form 225 CSE Specifications

General IconGeneral
BrandPro-Form
Model225 CSE
CategoryElliptical Trainer
LanguageEnglish

Related product manuals