V1.0 145A MULTI-PROCESS MIG-ARC-TIG WELDER 8619470
Visit www.princessauto.com for more information 35
APPENDIX A
APPENDIX B
When the overcurrent indicator illuminates and the digital meter displays
‘E-1’, it indicates that overcurrent occurs. Restart the machine, and welding
can be continued.
When the under-voltage indicator illuminates and the digital meter displays
‘E-2’, it indicates that the mains voltage is overly low, and welding can be
recovered when the mains voltage goes into normal.
When the overheating indicator illuminates and the digital meter displays
‘E-3’, it indicates that welding is forced to stop because the main circuit of the
machine gets overheated. In this condition, It is unnecessary to turn off the
machine, but just wait a few minutes, and then welding can be continued.
When the current sensor fails and the digital meter displays ‘E-4’, welding
may still be carried out. However, the current value at this time is inaccurate.