Do you have a question about the Proceq PAROTESTER 2 and is the answer not in the manual?
Storage Temperature | -20°C to 60°C |
---|---|
Display | LCD |
Power Supply | 4 x AA batteries |
Measurement Principle | Rebound method |
Probe Types | Standard probes and special probes |
Operating Temperature | 50°C |
Instructions for safe operation and maintenance of the PAROTESTER impact device.
Intended use and limitations of the PAROTESTER impact device and display device.
Exclusions for warranty and liability claims due to specific causes.
Advice on regular maintenance and component care for the device.
Compatibility of impact devices with the PAROTESTER2.
Data upload options to PC using PAROLINK/PAROLINK3 software.
Barcode reader connection requirements and power supply.
Requirements for printing data via RS232.
How to avoid damage to the device and impact body.
Factors affecting measurement accuracy and speed.
Detailed explanation of the PAROTESTER measuring principle.
Definition and calculation of the L-value in hardness testing.
Accuracy of the PAROTESTER (EQUO process) using L-value.
Specifications for the PAROTESTER2 display device.
Technical specifications for different impact device types.
Identification of controls and connections on the display device.
Illustration and description of impact device types.
Features and advantages of the electronic display device.
Details of connection ports on the PAROTESTER2 device.
Initial setup and power-on procedure for the device.
Essential settings required before measurement.
How to enter and manage roll identification numbers.
Procedure for uploading measurement data to a PC.
How to erase all stored measurement data from the device.
Transferring data to a printer in real-time.
Uploading data to a PC in real-time.
General guidelines for operating the PAROTESTER impact devices.
Explanation of the elements shown on the device's LCD screen.
How to read and understand measurement results and graphs.
How measurement limits are signaled and displayed.
Message indicating measurement speed is too high.
Displays signal failure with related values.
Detailed explanation of various signal errors and their causes.
General care and cleaning instructions for impact devices.
Software for uploading measurement data to a PC.
Accessory for reading roll identification via barcode.
Calibrated block for functional checks of impact devices.
Options for printing measurement data.
How to access and view stored measurements on the device.
Overview of the components included in the PAROTESTER2 package.
Details of the PAROTESTER2 display and impact device U.