Document # MAN0001 Issue 4.29 Page 11 of 34
Indications
Indicators
Colour visual status indication can be found on the rear edge of the controller and repeated at the
Keypad or Credential readers if these are connected. These indicators have the following meanings.
Keypad Status LED
Meaning
Blue
Normal Standby
Green
Lock released
Flashing
Programming Mode
Flashing with Strobe Light
Alarm
Blue with 4 red Flashes
Access denied
Sound
The sound is used to give the user additional feedback on the status of the controller and progress
during programming.
Sound
Meaning
Continuous Two Tone, High Volume
Door Alarm
Four Notes “Low High Low High”
Programming Mode
Two Notes “Low High”
Confirm Programming Change
Two Notes “High – Low “
Programming Error
Single Short Note “High”
Keypad Key Push
3 long Beeps
Credential not in memory
Door Alarm
The Prolonged Door Open (PDO) or “Door Failed to Close” alarm acts as a reminder that a door is
a security door and should not be wedged or held open. If the door sensor has been connected then
each time the door is detected opening, the PDO timer starts. If this timer reaches a pre-set value
before the door closes, a PDO alarm will be heard from the Controller-Keypad and any externally
connected readers.
PDO alarm cancels automatically when the door is closed. The PDO alarm is not active if the door is
open due to Toggle mode.