53TriStar MPPT Operator’s Manual
52
Networking and Communication
5.2 Morningstar MeterBus
TM
Morningstar’s proprietary MeterBus
TM
protocol allows communication between compatible
Morningstar products. Use a MeterBus
TM
network to:
• display net system data for multiple TriStar / TriStar MPPT 150V systems**
• communicate with a TriStar Digital Meter 2 or TriStar Remote Meter 2
• communicate with a Relay Driver or other compatible Morningstar accessories (see sec-
tion 2.5 for more details)
**A Morningstar MeterBus Hub (HUB-1) and either a TriStar Digital Meter 2 (TS-M-2) or TriStar Remote Meter 2 (TS-RM-2) are re-
quired, not included.
A MeterBus Hub (model: HUB-1) is required for MeterBus networks containing multiple
TriStar MPPT 150V controllers. The ports on the hub are electrically isolated to prevent damage in
the event of broken grounds or voltage dierences between controllers. Figure 5-1 below shows an
example MeterBus
TM
network with two (2) TriStar MPPT 150V controllers and a TriStar Remote Meter
2 (TS-RM2).
MeterBus
TM
Network Hub
TriStar
Controllers
Figure 5-1. An example MeterBus network.
Up to ve (5) controllers can be networked together with a single hub. Multiple hubs can be daisy-
chained together to allow networks of up to 14 controllers and a meter.
Refer to the HUB-1 and TriStar Meter manuals for more information about Morningstar MeterBus
TM
networking.
5.3 Serial RS-232
The serial port connection on the TriStar MPPT 150V is a standard 9-pin isolated RS-232 port. See
gure 3-5 for the port location.The TriStar MPPT 150V communicates through the serial port via the
open standard MODBUS
TM
protocol.
Connect the TriStar MPPT 150V to the serial port on a PC to:
• program custom charge settings with MSView
TM
PC software
• view real-time data with MSView
TM
PC software
• log real-time data with MSView
TM
PC software
• congure ethernet settings
• update controller rmware with MSLoad
TM
rmware utility
NOTE:
The RS-232 and EIA-485 ports share hardware. Both ports cannot be used
simultaneously.
NOTE:
If your PC does not have a serial port, a USB to Serial cable can be purchased
at your local electronics retailer.
The serial connection is ideal for conguring custom settings or monitoring a single
TriStar MPPT 150V controller. Figure 5-2 shows a serial connection between the controller and a PC
with MSView
TM
PC software.
Serial Cable
Figure 5-2. A serial connection between a PC and the TriStar MPPT 150V