The battery monitor is connected to a Cerbo GX
and a GX Touch screen.
3.10. Wiring for use as DC meter
When using the battery monitor as a DC meter, wire it to the device or circuit that needs to be monitored.
Note that the battery monitor also needs to be configured as a DC monitor using the VictronConnect app
before it will operate as a DC monitor
. See the Configure for use as DC meter [17] chapter.
It is also possible to have a main battery monitor in the system together with a separate battery monitor that has been set up as a
DC meter to monitor a specific device or circuit.
Wiring example of a system containing a main battery monitor, together with a battery monitor that has been set up as a DC
meter and is monitoring a specific device or circuit. One battery monitor is used as a DC meter (B) and the other battery monitor
is used as a battery monitor (D).
# Description
A Specific DC device or DC circuit
B Battery monitor used as DC meter
C The rest of the DC circuit
D Battery monitor used as battery monitor
Manual - BMV-712 Smart
Page 11 Installation