Loading...
Measured voltage Assumed nominal voltage
> 36V 48V
Note that the battery monitor is unable to detect a 32V nominal battery voltage. If the battery monitor is used
with a 32V battery bank, the charged voltage must be set manually using the Charged voltage
[29] setting.
4.3. How to change settings
4.3.1. Settings via the head unit
Use the display buttons to enter and navigate through the settings menu. Each setting has a number and a name. For example:
"01 - Battery capacity". The full list of all battery settings and their corresponding number can be found in the All features and
settings [28] chapter
.
It is also possible (and easier) to make the battery monitor settings via the VictronConnect app. See the The
V
ictronConnect app [14] chapter on how to do this.
Display
+ (up) and - (down)
buttons
Select
button
Setup
button
BMV head unit display and buttons.
To access the settings menu and change settings:
1 Start in the main menu.
2 Press SETUP for two seconds to enter the settings menu.
3 The first setting item 01-Battery capacity will be shown.
4 Use the + and – buttons to go to the desired setting item.
5 Press SELECT to access the setting item.
6 Use SELECT and the + and – buttons to customize the setting.