# Display Discription
P Lowest AUX voltage
Q Highest AUX voltage
R Discharged energy
S
Charged energy
5.5.3. History data
Discharge information in Ah
Deepest discharge: The battery monitor remembers the deepest discharge and each time the battery is discharged deeper
the old value will be overwritten.
Last discharge: The battery monitor keeps track of the discharge during the current cycle and displays the largest value
recorded for Ah consumed since the last synchronisation.
A
verage discharge: The cumulative Ah drawn divided by the total number of cycles.
Cumulative Ah drawn: The cumulative number of Amp hours drawn from the battery over the lifetime of the battery monitor.
Energy in kWh
Discharged energy: This is the total amount of energy drawn from the battery in kWh.
Charged energy:
The total amount of energy absorbed by the battery in kWh.
Charge
Total charge cycles: The number of charge cycles over the lifetime of the battery monitor. A charge cycle is counted every
time the state of charge drops below 65% and then rises above 90%.
Time since last full charge: The number of days since the last full charge.
Synchronisations: The number of automatic synchronisations. A synchronisation is counted every time the state of charge
drops below 90% before a synchronisation occurs.
Number of full discharges: The number of full discharges. A full discharge is counted when the state of charge reaches 0%.
Battery voltage
Min battery voltage: The lowest battery voltage.
Max battery voltage: The highest battery voltage.
Min starter voltage: The lowest auxiliary battery voltage (if applicable).
Max starter voltage: The highest auxiliary battery voltage (if applicable).
Voltage alarms
Low voltage alarms: The number of low voltage alarms.
High voltage alarms: The number of high voltage alarms.
5.6. Alarms
The battery monitor can raise an alarm in the following situations:
Low battery state of charge (SOC).
Low battery voltage.
High battery voltage.
Low and high starter battery voltage (if the AUX input has been set to "Starter battery").
Midpoint voltage (if the AUX input has been set to "Midpoint").
High and Low battery temperature (if the AUX input has been set to "Temperature").
Manual - BMV-712 Smart