Installation Guide
DCM 2 series
Aquatic Water Quality Controller
ProMinent Fluid Controls 136 Industry DrivePittsburgh, PA, USA 15275-1014 DCM 2 Installation Guide 12/9/16
Question and Answer IconNeed help?

Do you have a question about the ProMinent DCM 2 Series and is the answer not in the manual?

ProMinent DCM 2 Series Specifications

General IconGeneral
TypeController
SeriesDCM 2 Series
Input Voltage100-240 VAC, 50/60 Hz
Protection ClassIP65
Measured variablespH, Conductivity, Temperature
Output signalsrelay
Control functionsPID control
Communication protocolsModbus
Operating Temperature0°C to +50°C
Housing MaterialPlastic
DisplayLCD
Relative Humidity10 – 95 % (non-condensing)

Summary

Overview

Installation and Commissioning

2.1. Safety

Essential safety guidelines, including general precautions, electrical hazards, and configuration risks for safe installation.

2.2. Mounting

Guidelines and procedures for securely mounting the controller and sensor housing, considering location and environmental factors.

2.3. Wiring

Detailed instructions for connecting power, sensors, pumps, and other components according to electrical codes and safety standards.

Calibrations

3.1. Single Point Calibrations, One-Point or Standardization

Covers single point calibration for pH, Free Chlorine, and Temperature sensors, and contact set inputs.

3.2. Two Point Calibration

Details the process for two-point calibration, primarily applicable to pH sensors, involving OFFSET and GAIN adjustments.

Password Security

4.1. Overview

Explains the four password levels (Public, Operator, Configure, Administrator) for controller access and activity logging.

4.2. Password Level Activities

Details the specific activities allowed for each password level, including user IDs and default passwords.

Application Notes

5.1. Sensor Inputs & Control Outputs

Describes the controller's sensor inputs (A-F) and control outputs (relays 1-5, DC outputs) for various signals and devices.

5.2. Communications

Covers Ethernet LAN TCP-IP for web server access and USB services for data logging extraction.

5.3. Control Configuration

Details control configuration methods, including ON/OFF controls, frequency controlled pumps, and special control responses.

Sensors

6.1. Compensation

Explains sensor compensation methods for thermal (pH) and rate-to-volume sensors to ensure accurate measurements.

6.4. Frequency Controlled Pumps

Discusses feed rate setting for frequency controlled pumps based on sensor values or manual setpoints.

6.5. Technical: Pump Frequency-Stroke Controls

Provides technical details on pump frequency-stroke controls, including defaults, ranges, and maximum feed rates.

6.6. Relay & Frequency Controls Comparison

Compares ON/OFF controls with frequency controls for relays and DC outputs, detailing their functions and applications.

6.7. System Alarms & Indicating LEDs

Explains system alarms, their causes and effects, and the functions of indicating LEDs on the controller.

6.8. Units for Volumes & Temperatures

Details the selection and application of Metric and US units for volumes, water meters, and temperature measurements.

Spare Parts