ProMinent DULCOMETER User Manual

ProMinent DULCOMETER
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DULCOMETER
®
Multi-parameter Controller diaLog DACa
Assembly and operating instructions
A1111
Part no. 985250 BA DM 203 04/14 EN
Please carefully read these operating instructions before use! · Do not discard!
The operator shall be liable for any damage caused by installation or operating errors!
Technical changes reserved.

Table of Contents

Other manuals for ProMinent DULCOMETER

Question and Answer IconNeed help?

Do you have a question about the ProMinent DULCOMETER and is the answer not in the manual?

ProMinent DULCOMETER Specifications

General IconGeneral
Protection ClassIP65
Measurement ParameterspH, Conductivity, Temperature
CommunicationModbus
Power Supply24 V DC or 100-240 V AC
Control OutputsRelay, Analog (0/4-20 mA)
Control FunctionsPID control
Input SignalsAnalog (0/4-20 mA), Digital
MountingWall-mounted, panel-mounted
Measurement Range pH0-14 pH
Measurement Range Conductivity0-2000 µS/cm

Summary

Operating Concept

Acknowledging Error or Warning Messages

How to acknowledge and handle error and warning messages.

Safety and Responsibility

Explanation of the safety information

Details the meaning of safety symbols and categories used in the manual.

General safety notes

Provides essential safety guidelines for operating the device.

Users' qualifications

Specifies the required qualifications for personnel operating the device.

Functional description

Assembly and installation

Electrical installation

Covers the electrical connections and wiring for the controller.

Connect the sensors electrically to the controller

Instructions for connecting various sensors to the controller.

Commissioning

Setting measured variables

Calibration

Calibrating the pH sensor

Procedure for calibrating the pH sensor for accurate measurements.

Calibrating the ORP Sensor

Instructions for calibrating the ORP sensor.

Calibrating the Fluoride Sensor

Steps for calibrating the fluoride sensor.

Calibrating Amperometric Sensors

General process for calibrating amperometric sensors.

Calibrating Oxygen Sensors

Procedure for calibrating oxygen sensors.

Calibrating conductivity

Instructions for calibrating conductivity measurements.

Calibrating temperature

Procedure for calibrating temperature measurements.

Setting the [Control]

Control parameter [Setpoint]

Specifies the target value for the control loop.

Setting the [Limit values]

Setting the [Pumps]

Setting the [Relays]

Setting [Digital inputs]

Setting the [mA outputs]

Setting the [mA outputs]

Configuration of the controller's mA output channels.

Function: Data logger

[Diagnostics]

Error messages and warning alerts

List of error codes, their causes, and remedies.

Setting [Device setup]