17
[Diagnostics]
n User qualification: instructed user,
see
Ä Chapter 4.4 ‘Users' qualifica‐
tions’ on page 21
Continuous display ➨ or
[Diagnostics]
[Diagnostics]
It is possible to look through log books,
perform a simulation of outputs or view
device information in this menu.
Diagnostics
Logbook
A0981
9.1
Simulation
Device information
Fig. 111: Diagnostics
17.1 Displaying
[logbooks]
Continuous display ➨ or
[Diagnostics]
[Diagnostics]
or
[Calibration log book]
[Calibration log book]
Log books
Calibration log book
A0982
9.1.1
Error log book
Data log book
Fig. 112: Displaying [Log books]
17.1.1
Displaying the
[Calibration Log Book]
The data on the sensor calibrations suc‐
cessfully completed are stored in the
internal
[Calibration log book]
. Up to 30
calibrations can be stored. Thereafter the
oldest entry is overwritten with the most
recent entry.
The following data is stored:
n Name of the measuring channel
n Measured variable
n Time of calibration
n Zero point
n Slope
Deleting entries in
the
[Calibration log book]
You can also delete entries in the Calibra‐
tion log book. Deleting the entries does
not affect the calibrations stored in the
controller.
17.1.2
Reading the
[Error Log Book]
The error message data is stored in the
[Error log book]
. Up to 30 error messages
can be stored. Thereafter the oldest entry
is overwritten with the most recent entry.
[Diagnostics]
146

Table of Contents

Other manuals for ProMinent DULCOMETER

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent DULCOMETER and is the answer not in the manual?

ProMinent DULCOMETER Specifications

General IconGeneral
Protection ClassIP65
Measurement ParameterspH, Conductivity, Temperature
CommunicationModbus
Power Supply24 V DC or 100-240 V AC
Control OutputsRelay, Analog (0/4-20 mA)
Control FunctionsPID control
Input SignalsAnalog (0/4-20 mA), Digital
MountingWall-mounted, panel-mounted
Measurement Range pH0-14 pH
Measurement Range Conductivity0-2000 µS/cm

Related product manuals