DULCOMETER
®
Multi-parameter Controller diaLog DACa
Assembly and operating instructions
A1111
Part no. 985250 BA DM 203 04/14 EN
Please carefully read these operating instructions before use! · Do not discard!
The operator shall be liable for any damage caused by installation or operating errors!
Technical changes reserved.

Table of Contents

Other manuals for ProMinent DULCOMETER

Questions and Answers

  • D
    Douglas SimpsonAug 21, 2025
    What causes the pH/mV RANGE? error on a ProMinent DULCOMETER Controller?
    • S
      Stephen LutzAug 21, 2025
      The 'pH/mV RANGE?' error on your ProMinent Controller can be caused by the input voltage being too high. The suggested solution is 'Fault current'.
  • D
    Daniel DeleonSep 3, 2025
    What does NO PROBE mean on a ProMinent DULCOMETER?
    • M
      Mike Brown MDSep 3, 2025
      If 'NO PROBE' is displayed on your ProMinent Controller and pH sensor monitoring is activated, it indicates there is no sensor. The suggested solution is 'Fault current'.
  • J
    jacob35Sep 1, 2025
    What does PROBE ERR mean on my ProMinent Controller?
    • K
      keith32Sep 1, 2025
      If the 'PROBE ERR' is displayed, and pH sensor monitoring is activated, it indicates a sensor break. The suggested solution is 'Fault current'.
  • T
    Tiffany TaylorAug 30, 2025
    Why does my ProMinent DULCOMETER show CHECK? TIME?
    • D
      David SalasAug 30, 2025
      The 'CHECK? TIME' message indicates that the control checkout time has elapsed. The suggested solution is 'Fault current'.
  • M
    Michelle KingAug 29, 2025
    What does TLIMITERR mean on a ProMinent Controller and how to fix it?
    • L
      larryandrewsAug 29, 2025
      The 'TLIMITERR' indicates that the set checkout time for monitoring the correction variable limits has elapsed. The suggested solution is 'Fault current'.
  • V
    Victoria GreenAug 27, 2025
    What does 'NO CAL' mean on my ProMinent DULCOMETER Controller?
    • M
      Mike Brock IIAug 28, 2025
      The 'NO CAL' message on your ProMinent Controller means that no valid user calibration exists.
  • R
    Rebecca AdkinsAug 26, 2025
    Why does my ProMinent DULCOMETER Controller display 'pH/mV RANGE'?
    • M
      Misty NguyenAug 26, 2025
      The 'pH/mV RANGE' error on your ProMinent Controller can appear if the input voltage is either too low or too high, indicating a fault current.
  • L
    luismillsAug 25, 2025
    What does NO CAL mean on my ProMinent DULCOMETER Controller?
    • C
      Charles LynchAug 25, 2025
      The 'NO CAL' message indicates that no valid user calibration exists.
  • E
    ericbradfordAug 23, 2025
    What does CAL ERROR mean on ProMinent Controller?
    • K
      Kimberly HoldenAug 23, 2025
      The 'CAL ERROR' indicates that no valid user calibration exists.

Summary

Operating Concept

Acknowledging Error or Warning Messages

How to acknowledge and handle error and warning messages.

Safety and Responsibility

Explanation of the safety information

Details the meaning of safety symbols and categories used in the manual.

General safety notes

Provides essential safety guidelines for operating the device.

Users qualifications

Specifies the required qualifications for personnel operating the device.

Functional description

Assembly and installation

Electrical installation

Covers the electrical connections and wiring for the controller.

Connect the sensors electrically to the controller

Instructions for connecting various sensors to the controller.

Commissioning

Setting measured variables

Calibration

Calibrating the pH sensor

Procedure for calibrating the pH sensor for accurate measurements.

Calibrating the ORP Sensor

Instructions for calibrating the ORP sensor.

Calibrating the Fluoride Sensor

Steps for calibrating the fluoride sensor.

Calibrating Amperometric Sensors

General process for calibrating amperometric sensors.

Calibrating Oxygen Sensors

Procedure for calibrating oxygen sensors.

Calibrating conductivity

Instructions for calibrating conductivity measurements.

Calibrating temperature

Procedure for calibrating temperature measurements.

Setting the [Control]

Control parameter [Setpoint]

Specifies the target value for the control loop.

Setting the [Limit values]

Setting the [Pumps]

Setting the [Relays]

Setting [Digital inputs]

Setting the [mA outputs]

Setting the [mA outputs]

Configuration of the controller's mA output channels.

Function: Data logger

[Diagnostics]

Error messages and warning alerts

List of error codes, their causes, and remedies.

Setting [Device setup]

ProMinent DULCOMETER Specifications

General IconGeneral
Protection ClassIP65
Measurement ParameterspH, Conductivity, Temperature
CommunicationModbus
Power Supply24 V DC or 100-240 V AC
Control OutputsRelay, Analog (0/4-20 mA)
Control FunctionsPID control
Input SignalsAnalog (0/4-20 mA), Digital
MountingWall-mounted, panel-mounted
Measurement Range pH0-14 pH
Measurement Range Conductivity0-2000 µS/cm