3FBEh user pump location
0 number of entries U8 8 ro
1 location string[4] location character 29 - 32 ro
2 location string[4] location character 25 - 28 ro
3 location string[4] location character 21 - 24 ro
4 location string[4] location character 17 - 20 ro
5 location string[4] location character 13 - 16 ro
6 location string[4] location character 9 - 12 ro
7 location string[4] location character 5 - 8 ro
8 location string[4] location character 1 - 4 ro
6509 0 Al1_action=1 warn,=3 err U8 Level min error ro
6519 0 Al2_action U8 Level min warning ro
6529 0 Al3_action U8 Batch error ro
6539 0 Al4_action U8 Cal warning ro
6549 0 Al5_action U8 Sys error ro
6559 0 Al6_action U8 Bus off ro
6569 0 Al7_action U8 add2 ro
6579 0 Al8_action U8 add3 ro
6600 0 Al_state0_7 U8 0=no error, 1=error
B Explicació n de los objetos
DeviceState [Index 0x2A10, Subindex 0x00]
El objeto ‚DeviceState’ contiene estados de funcionamiento actuales y fallos pendientes de la
bomba. El ‚DeviceState’ sólo se puede leer.
Bits Significado
15 (MSB) Funcionamiento manual / de Bus
14 Pausa
13 Fallo interno
12 Fallo interno
11 Modo de funcionamiento: 1 continuo
10 2
Funcionamiento batch
9 3 Contacto externo
8 4 Entrada analógica
7 Parada
6 Fallo interno
5 Advertencia (p.ej., estado de llenado del recipiente)
4 Aspiración activada
3 Contrataladro (sólo en instalaciones de ProMinent)
2 La calibración no es válida
1 Depósito de dosificación
0 (LSB) Teleoperación imposible
Tabla: 1 DeviceState BitValues