ProMinent
®
Page 37
Message: lamp
(only in systems with an electronic ballast)
Press the ENTER key to acknowledge the fault message
Possible cause Faulty lamp.
Remedy
Insert a new lamp
Possible cause Faulty ballast.
Remedy
Replace the ballast
Possible cause Interruption of least one phase in the power supply
Remedy Check the power supply
Message: lamp current
(only in systems with a conventional ballast)
Press the ENTER key to acknowledge the fault mess
Possible cause Faulty lamp.
Remedy Lamp
Possible cause Faulty ignition device.
Remedy Replace ignition device
Message: earth leakage
(only in systems with an electronic ballast)
Press the ENTER key to acknowledge the fault message
Possible cause Moisture in the lamp’s protective tube.
Remedy Dry the lamp and protective tube and check the seals
Possible cause Lamp cable damaged.
Remedy Replace lamp cable
Message: temperature measurement
Press the ENTER key to acknowledge the fault message
Possible cause Faulty temperature gauge.
Remedy
Replace temperature gauge
Message: water temperature too high
Press the ENTER key to acknowledge the fault message
Possible cause Inadequate water flow.
Remedy Increase water flow
Possible cause Flushing valve does not open.
Remedy Replace flushing valve
Possible cause Flushing valve too small.
Remedy Replace flushing valve
Troubleshooting
Fault
Lamp current
Fault
Lamp
Fault
Earth leakage
Fault
Temperature
measurement
Fault
Water temperature
to high