ProMinent
®
Page 42
Data sheet
®
UVMa
Side view A
ø13
350
300
600
DF
L5
80
H
40
L1L2
L6
DR
L7
L6
DF
L4
L3
LA
1400
1142
630
229
A
300 deep
Ø
1
0.2
Cable length approx. 10 mtrs. each
Data sheet
IMPORTANT
This data sheet only applies to standard systems!
Subject to amendments!
Number Radiator Power Length of Minimum Diameter Curb Nominal
of capacity connection radiation clearance weight width
radiators chamber for changing of con-
the lamp nection
TYPE (kW) (kW) (mm)
1*2ML/22/DN100 1 2 2.3 850 900 220 146 DN 100
1*3ML/22/DN150 1 3 3.3 850 900 220 150 DN 150
1*4ML/27/DN200 1 4 4.2 1200 1250 270 190 DN 200
1*6ML/32/DN250 1 6 6.2 1200 1250 320 230 DN 250
1*8ML/32/DN250 1 8 8.2 1500 1550 320 240 DN 250
1*10ML/32/DN260 1 10 10.2 1500 1550 320 240 DN 250
1*10ML/4O/DN300 1 10 10.2 1500 1550 400 283 DN 300
Type Ll L2 L3 L4 L5 L6 L7 LA
øDF DR H Flange
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) DIN 2576 PN 10
1x2ML/22/DN100 - - 850 130 690 250 250 1750 220 219.1 - DN100x114.3
1x3ML/22/DN150 120 350 850 145 665 250 250 1750 220 219.1 125 DN150x168.3
1x4ML/27/DN200 - - 1200 175 990 325 240 2460 340 273 - DN200x219.1
1x6ML/32/DN250 250 450 1200 200 950 370 240 2450 395 323.9 175 DN250x273
1x8ML/32/DN250 350 630 1500 200 1250 370 240 3050 395 323.9 175 DN250x273
1x10ML/32/DN250 350 630 1500 200 1250 370 240 3050 395 323.9 175 DN250x273
1x10ML/40/DN300 350 630 1500 225 1225 400 240 3050 445 416.4 215 DN300x323.9
Requirements for the water to be treated:
• maximum temperature: 40 °C
• maximum operating pressure: 10 bar*)
• no corrosive or abrasive properties, chloride content < 250 ppm
• not liable to sediments
*) lower operating pressures are possible for specially designed systems!