14.4.3 Air humidity
Data Value Unit
Maximum air humidity *: 95 % rel.
humidity
* non-condensing
14.4.4 Degree of Protection and Safety Requirements
Protection against contact and humidity:
IP 55 in accordance with IEC 529, EN 60529, DIN VDE 0470 Part 1
Degree of protection:
1 - Mains power connection with protective earth conductor
14.5 Electrical connection
The electrical data do not relate to the motor, but the pump,
which is connected as a whole unit.
For the motor electrical data use the motor data sheet
1018455, 1018432, 1018433 in the appendix.
Identity code specification "power supply" - "U": 100 - 230 V ± 10 %, 50/60
Hz
Electrical data at 100 V
Data Value Unit
Nominal power 250 W
Nominal current 3.2 A
Peak current during operation* 10 A
Switch on peak current, (for approx. 100
ms)
12 A
Electrical data at 230 V
Data Value Unit
Nominal power 250 W
Nominal current 2.0 A
Peak current during operation* 5.5 A
Switch on peak current, (for approx. 100
ms)
24 A
* internal switchover
Fuses
Fuse Value Part no.
Fuse, internal 4.0 AT - (1.5 kV) 732497
Air humidity
Degree of protection
Safety requirements
Electrical data S2Ca pump
Technical data