Page #1 background image
Power Harmonics and Leakage Tester
Model 21/23
Leakage and Harmonics Tester
Model 19
Users Manual
3
3
m
ERR
AUTO-POWER-OFF
Ture RMS
PROVA INSTRUMENTS INC.
Question and Answer IconNeed help?

Do you have a question about the PROVA 21 and is the answer not in the manual?

PROVA 21 Specifications

General IconGeneral
ContinuityYes
Diode TestYes
Input Impedance10MΩ
Power Supply9V battery
DisplayLCD
Resolution (Voltage)0.1mV

Summary

Product Features

Panel Description - Controls

Transformer Jaw Assembly

Component used to pick up current signals by enclosing conductors.

Transformer Trigger

Button to open the transformer jaw for conductor insertion.

Rotary Switch

Used to turn on power and select measurement modes (current, voltage, power).

MAX/MIN/HOLD/PEAK and Button

Button for MAX, MIN, HOLD, PEAK functions and decrementing harmonics/CT ratio.

Panel Description - Buttons and Interface

3 Button

Increments harmonics/CT ratio, selects 3-phase power or AUTO Hz.

FUNC Button

Selects measurement functions like harmonics, THD, CF, VA, VAR, PF, HP, Energy.

LCD Display

4+2+2 digit display showing function symbols, units, and measurement values.

Display Symbols

Symbols for selected functions like Harmonic, PEAK, MAX, MIN, HOLD.

Primary Digits

Displays measurement values for current, voltage, or power.

Symbols of Units

Indicates units of current, voltage, power, and fundamental frequency.

V Input Terminal

Input terminal for voltage and power measurements.

COM Terminal

Common reference input terminal.

Hand Strap

Strap to prevent accidental dropping of the clamp meter.

Panel Description - Sliding Switch

Sliding Switch Function

Selects fundamental frequency (50/60 Hz) for measurements.

Operating Instructions: AC Current Measurement

AC mA and A Measurement Procedure

Steps for measuring AC current in mA and A ranges.

True RMS Value of AC Current

Procedure to measure the true RMS value of AC current.

HOLD, MAX, MIN, PEAK Functions for AC Current

Using HOLD, MAX, MIN, and PEAK functions for AC current.

Harmonics of AC Current (Magnitude)

Measuring the magnitude of AC current harmonics (1 to 99th order).

Harmonics of AC Current (Percentage)

Measuring AC current harmonics as a percentage of the fundamental.

Total Harmonic Distortion (% THD-F) of AC Current

Calculating and displaying total harmonic distortion for AC current.

Crest Factor (C.F.) of AC Current

Measuring and displaying the crest factor of AC current.

Frequency of AC Current

Measuring and displaying the frequency of AC current.

Operating Instructions: AC Voltage Measurement

AC Voltage Measurement Overview

Instructions and notes for measuring AC voltage.

True RMS Value of AC Voltage

Procedure to measure the true RMS value of AC voltage.

HOLD, MAX, MIN, PEAK Functions for AC Voltage

Using HOLD, MAX, MIN, and PEAK functions for AC voltage.

Harmonics of AC Voltage (Magnitude)

Measuring the magnitude of AC voltage harmonics (1 to 99th order).

Harmonics of AC Voltage (Percentage)

Measuring AC voltage harmonics as a percentage of the fundamental.

Total Harmonic Distortion (% THD-F) of AC Voltage

Calculating and displaying total harmonic distortion for AC voltage.

Crest Factor (C.F.) of AC Voltage

Measuring and displaying the crest factor of AC voltage.

Frequency of AC Voltage

Measuring and displaying the frequency of AC voltage.

Operating Instructions: Single-Phase Power Quality

Single-Phase AC Power Quality Measurement

Instructions for measuring single-phase AC power quality.

Single-Phase AC Watt Measurement

Procedure to measure single-phase AC wattage.

Apparent and Reactive Power Measurement

Measuring apparent power (VA, KVA) and reactive power (VAR, KVAR).

Power Factor and Phase Angle Measurement

Measuring power factor (PF) and phase angle (Φ).

Horse Power (H.P.) Measurement

Measuring and displaying power in Horse Power (HP).

Energy Measurement (mWH, WH, KWH)

Measuring and displaying energy consumption in mWH, WH, or KWH.

Operating Instructions: Balanced 3-Phase Power Quality

Balanced 3-Phase AC Power Quality Measurement

Instructions for measuring balanced 3-phase AC power quality.

Operating Instructions: Balanced 3-Phase Sequence

Balanced 3-Phase Sequence Measurement

Measuring and displaying the sequence of balanced 3-phase power systems.

Configuration and Settings

Setting the CT Ratio

Procedure for setting the Current Transformer (CT) ratio.

Disabling Auto-Power-Off

How to disable the automatic power-off function.

Specifications: AC Watt

AC Watt Specifications (Model 21, 23)

Technical specifications for AC Watt measurements for Model 21 and 23.

Specifications: Power Formulas and Extended Ranges

AC Watt Specifications (Extended Ranges)

Extended range specifications for AC Watt measurements.

Power Measurement Formulas and Ratios

Formulas for HP, Apparent Power, Reactive Power, and Active Energy.

Specifications: AC Current

AC Current Specifications (Model 19, 21, 23)

Technical specifications for AC current measurements for Model 19, 21, and 23.

Specifications: AC Voltage and Harmonics

AC Voltage Specifications (Model 19, 21, 23)

Technical specifications for AC voltage measurements for Model 19, 21, 23.

Harmonics of AC Voltage (Percentage)

Specifications for AC voltage harmonics in percentage.

Specifications: AC Voltage Magnitude and AC Current Harmonics

Harmonics of AC Voltage (Magnitude)

Specifications for AC voltage harmonics in magnitude.

Harmonics of AC Current (Percentage)

Specifications for AC current harmonics in percentage.

Specifications: AC Current Harmonics, PF, Phase Angle, Frequency

Harmonics of AC Current (Magnitude)

Specifications for AC current harmonics in magnitude.

Power Factor, Phase Angle, and Frequency Specs

Specifications for Power Factor, Phase Angle, and Frequency measurements.

Specifications: Distortion, Peak Value, Crest Factor

Total Harmonic Distortion (THD-F) Specifications

Specifications for Total Harmonic Distortion (THD-F) measurements.

Peak Value and Crest Factor Specifications

Specifications for Peak Value and Crest Factor measurements.

General Specifications and Usage Conditions

Indoor Use Specifications

Parameters like conductor size, display, overload, power consumption, and auto-off.

Environmental and Physical Specifications

Temperature, humidity, altitude, storage, dimension, and weight details.

Included Accessories and Options

List of standard accessories and optional items for the device.

Battery Replacement

Procedure for Battery Replacement

Step-by-step guide to replace the batteries in the device.

Maintenance and Cleaning

Servicing and Cleaning Guidelines

Guidelines for servicing, repairs, and cleaning the device case.