EasyManua.ls Logo

Prozeda Solareg II BASIC HE - Troubleshooting; Faults with Error Messages

Prozeda Solareg II BASIC HE
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
9 Troubleshooting
In principle, all system errors can be placed in one of two categories:
Faults that the controller can detect automatically and for which error mes-
sages can be shown
Faults that cannot be reported by the controller
9.1 Faults with error messages
Error displayed
on-screen
Possible causes Action to take
ashing
Disruption to sensor
cable
Check cable
Sensor defective
Check sensor resistance,
replace sensor if neces-
sary
ashing
Short-circuit in sensor
cable
Check cable
Sensor defective
Check sensor resistance,
replace if necessary
Circulation fault:
no ow-through
+
ashing
Fault in pump connection
Check cabling
Pump defective
Replace pump
Air in the system
Vent system
Disruption to sensor
cable
Check cable
Sensor defective
Check sensor resistance,
replace sensor if neces-
sary