Programming Guide 127
Label Length
Format
Follow the steps below to set the MSI/Plessey label length format to
either the Variable Length or Fixed Length format.
Variable Length
Format
Follow the steps below to set the MSI/Plessey to read Variable Length
Format.
1. Identify the minimum length setting you want to make. The
selectable range is 04 to 16 characters.
2. Scan the SET bar code.
3. Scan the ENABLE VARIABLE LENGTH FORMAT bar code.
4. Scan the SET MINIMUM LABEL LENGTH bar code.
5. Set the minimum label length by scanning the applicable digits
bar codes on page 130. Return to this page.
6. Scan the END bar code.
NOTE
If you are setting a label length less than ten, you
must scan a zero digit first and then the length
digit (e.g., 04, 06, 08).
Variable Length
SET ------------------------------------------
Enable Variable Length
Format ---------
Set Minimum Label
Length ---------
END ------------------------------------------