Hydraulic system fluid should be changed at least once every 12 months.
For optimum performance over an extended period of time, the following preventive maintenance service should
be done every 12 months or 500 operating hours (whichever comes first):
1) Disconnect all hydraulic hoses and remove the winch from its mounting.
2) Disassemble the winch as per instructions.
3) Discard and replace all O-rings and oil seals.
4) Clean all parts and inspect for wear and damage as per instructions. Replace worn or damaged
parts as required.
5) Reassemble the winch as per instructions.
6) Follow INSTALLATION and OPERATING INSTRUCTIONS when returning winch to its mounting.
When ordering parts for the PULLMASTER Model M50 free fall planetary winch, always quote the complete
model and serial number of the unit.
MODEL # ____________________
SERIAL # ____________________RNI
PULLMASTER WINCH CORPORATION reserves the right to change specifications and the design of
PULLMASTER planetary winches at any time without prior notice and without incurring any obligations.