EasyManua.ls Logo

Puratech 5100 - Service Settings and Operating Modes; Advanced Service Settings and Modes

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PuraTech
®
Owner’s Manual 12/11/2013 17
Service Settings, Cont.
Display
Meaning
Possible Values
Comments
Brine/Rinse
30.0
Number of minutes the
brine and slow rinse cycle
lasts
00.0 to 99.9
Set to the nearest tenth of a minute
Backwash 2
02.0
Number of minutes the
second backwash cycle
lasts
00.0 to 99.9
Set to the nearest tenth of a minute
Salt lbs.
06.0
Amount of salt set to be
used in each regeneration
to achieve the capacity
setting
00.0 to 99.9 lb (kg)
Set to the nearest tenth
Turbine Test
No
Used by qualified
personnel for diagnostic
purposes
No or Yes
Do not engage this feature
Reg. Tonight
No
Sets the appliance to
regenerate tonight
No or Yes
If set to Yes, it will force a
regeneration at the next set
regeneration time (such as 02:00
AM). After the regeneration, the value
will be set to No
Filter?
No
Used by qualified service
personnel to set the model
number
No or Yes
Has no effect on the function of the
appliance
When you press the Display button at “Filter?”, the values are saved, and the controller returns to Normal
operating mode.
Operating Modes
The appliance has two operating modes: Timer mode and Demand Delayed mode. Both modes are equipped
with Capacity Guard
®
, which ensures that a supply of conditioned water will be available even with excessive
water usage.
Mode 1Timer Mode
When the appliance is in Timer mode, it will regenerate based on the frequency that is set, for example every
day or up to every 12 days. The time of regeneration can be set.
Mode 2Demand Delayed Mode
When the appliance is in Demand Delayed mode, it will regenerate based on the actual water usage and the
total capacity of the appliance. The time that the regeneration takes place can be set, for example 2:00 AM.
Should the total capacity be depleted before the set regeneration time, a forced regeneration will occur.
7296 Hour Regeneration
If this value is set to Yes, the appliance will be forced to regenerate every 7296 hours unless a regeneration
based on water usage occurs within the time interval. The value should always be set to Yes if iron is present in
the water.