Page 8 iGen
®
Man u al
System Type
Regeneration
Option
Regeneration
Type
Day
Override
Softening Auto Normal 1-28 days
Regeneration occurs at the next regeneration time when
volume capacity falls below the reserve capacity, or the
speci ed number of days is reached, whichever comes rst.
Softening Auto Normal OFF
Regeneration occurs at the next regeneration time when
volume capacity falls below the reserve capacity.
Softening or
Filtering
20 – 50,000
Gallons
Normal 1-28 days
Regeneration occurs at the next regeneration time when
volume capacity reaches 0, or the speci ed number of days
is reached, whichever comes rst.
Softening or
Filtering
20 – 50,000
Gallons
Normal OFF
Regeneration occurs at the next regeneration time when
volume capacity reaches 0.
Softening or
Filtering
OFF Normal 1-28 days
Time Clock operation.
Regeneration occurs at the next regeneration time the
speci ed number of days is reached.
Softening
Auto or
20 – 50,000
Gallons
On 0 1-28 days
Regeneration occurs immediately when volume capacity
reaches 0, or the speci ed number of days is reached,
whichever comes rst.
Softening or
Filtering
20-50,000
Gallons
On 0 OFF
Regeneration occurs immediately when volume capacity
reaches 0.
Softening Auto
Normal +
On 0
1-28 days
Regeneration occurs at the next regeneration time when
volume capacity falls below the reserve capacity, or the
speci ed number of days is reached, or regeneration occurs
after 10 minutes of no water usage when volume capacity
reaches 0.
Softening or
Filtering
20 – 50,000
Gallons
Normal +
On 0
1-28 days
Regeneration occurs at the next regeneration time the
speci ed number of days is reached or regeneration occurs
after 10 minutes of no water usage when volume capacity
reaches 0.
Softening Auto
Normal +
On 0
OFF
Regeneration occurs at the next regeneration time when
volume capacity falls below the reserve capacity, or
regeneration occurs after 10 minutes of no water usage
when volume capacity reaches 0.
Setting Options Table
The control valve with a water meter can be set for
• Demand Initiated Regeneration (DIR) only
• Time Clock operation only
• DIR and Time Clock, whichever occurs rst, depending upon what settings are selected for Day Override and Gallon
Capacity
If a control valve does not contain a meter, the valve can only act as a time clock, and day override should be set to any
number and gallon capacity should be set to off.
The user can initiate manual regeneration. The user has the option to request the manual regeneration at the delayed
regeneration time or to have the regeneration occur immediately:
1. Press and release REGEN. “Regen Today” will ash on the display and the regeneration will occur at the delayed re
generation time. The user can cancel the request by pressing and releasing REGEN. NOTE: This method of manually
initiating regeneration is NOT allowed when the Regeneration Type is set to On 0.º
2. Press and hold REGEN for approximately 3 seconds to immediately start the regeneration. The user cannot cancel this
request, except by resetting the control by pressing NEXT and REGEN simultaneously for 3 seconds.
The control valve may be stepped through the regeneration cycles by pressing REGEN.