Procedure for replacing the 3-volt lithium coin cell battery.
Note on regenerant piston usage in backwash only applications.
Note on regenerant piston usage for WS1.25 model.
Details on softening operation parameters for various codes (C1-C32).
Details on filtering operation parameters for various codes (C41-C52).
Explanation of regeneration triggers: Demand Initiated, Time Clock, and combined modes.
Instructions on how to initiate manual regeneration and cancel requests.
Procedure to lock and unlock access to diagnostic and valve history displays and settings.
Information on display timeouts and how to exit setup procedures.
Steps 1S-3S: Valve type selection, softening choice, and system setup.
Steps 4S-5S: Setting ion exchange capacity and pounds of salt per regeneration.
Steps 6S-7S: Configuring backwash type and gallons capacity for softener setup.
Steps 8S-9S: Setting refill options and regenerant flow direction (downflow/upflow).
Step 10S: Configuring regeneration timing based on capacity or time.
Steps 1F-3F: Valve type, filter choice, and regeneration volume settings.
Steps 5F-7F: Configuring backwash type and brine tank refill options for filter setup.
Step 8F: Setting regeneration time based on capacity or day override for filter systems.
Steps 2I-3I: Setting water hardness and day override for regeneration.
Steps 4I-5I: Configuring the hour and minutes for the next regeneration time.
Steps 2SA-3SA: Setting media weight and time between service calls.
Steps 4SA-5SA: Resetting alarms and setting the service contact phone number.
Description of displays showing time, days/capacity remaining, and REGEN TODAY.
Information on how service alarms are displayed, showing time or volume remaining.
Explanation of displays during regeneration, showing process steps and time remaining.
How to initiate manual regeneration at a delayed time or immediately.
Procedure to set or reset the system's current time of day.
How the system handles power outages and battery depletion.
Explanation of error messages and when to contact OEM for assistance.
Steps 2D-3D: Displaying days and gallons treated since last reset.
Steps 4D-5D: Showing reserve capacity and 63-day usage history.
Step 6D: Displaying the current flow rate in gallons per minute.
Steps 7D-8D: Displaying max flow rate and total gallons used since reset.
Steps 9D-10D: Showing total days in service and total regenerations since reset.
Steps 2VH-3VH: Displaying software version and max flow rate since startup.
Steps 4VH-6VH: Showing total gallons, days, and regenerations since startup.
Step 7VH: Reviewing the history of the last 10 errors generated by the control.