USR-DR13X User Manual
pusr.com
- 22 -
Figure 17. Settings of system parameters
Table 10. Detail description of system parameters
Parameter Item
Description
Module name
The name of the device, up to 14 characters, can’t be null
Webserver port
Webserver listen port NO. The default is 80. Range 1-65535
Username
The username of web console and can be modified. up to 5 characters, can t be
NULL
Password
The password of web console and can be modified. up to 5 characters, can be NULL
Packing Time
If the time between two bytes received by serial port is greater than the set value, it
will be sent in two packets, otherwise it will be sent as one packet.
The default value is 0 ms, the range is 0~255ms.
Packing Length
When the length of data received by serial port reaches the set value, it is sent as a
packet.
The default is 400 bytes, and the range is 1~1024 bytes.
No data restart
This function is used for the serial device server without any data transmission or