TOOL MASTER Lite 14
11
MANUAL © Evoset AG
Enter offset values / working with adapters
If adaptors are used, must the engraved offset value of the adaptor be set as offset values in
the Z axis.
Procedure.
a) Press the SET key and hold it for 5 seconds to access the Programming Menu.
b) Press SET twice until OFFSETS is displayed and press ENTER.
c) Select the offset that you would like to use for the tool. Use SET and ABS/REL to select
the desired offsets and press the ENTER key to edit it.
d) Enter the calculated Offset Value. Use SET and ABS/REL to navigate between spaces and
CLEAR to increase the value. The first cell corresponds to the value's sign (positive or
negative).
- Example: Select the first digit and press CLEAR to make the value negative. Press SET to
edit the next digit to enter the engraved value on the adaptor.
e) Press ENTER once the value is set, and the display goes back to the OFFSETS menu.
Press CLEAR twice to exit to the main screen.
d) Select the chosen machine offset by pressing and holding the SET key followed by pressing
ABS/REL until the chosen offset is shown.
The Z-axis reference zero is now set for this particular adaptor.
Please see next page for further information

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PWB TOOL MASTER Lite 14 and is the answer not in the manual?

PWB TOOL MASTER Lite 14 Specifications

General IconGeneral
BrandPWB
ModelTOOL MASTER Lite 14
CategoryIndustrial Equipment
LanguageEnglish