PCX 46 Programming Reference
Page: 43
EVENT TYPES 10 = Batt/Bus/Mains/Line Faults
RS 485 Fault IA 1300
Low Volts AT 1302
Battery Critical YT 1302
Battery Load Fail YT 1309
Battery Missing YT 1311
Battery Restore YR 3311
Modem Failed 1330
Expansion Device Fail ET 1333
Expansion Device Restored ER 3333
Telecom Line Fault (modem) 1350
STU comms failure on STU input
indication.
LT 1351
Telecom line fault (modem) UB 1572
EVENT TYPES 11 = System Reset/Logs/Time
System Restart 1305
Reset To Factory Default 1305
Deleted Code JX 1306
Changed Code JV 1306
Site Changed YG 1306
Code Added JV 1306
Engineer reset needed 1313
Engineer Reset RN 3313
Logs Cleared 1621
Logs nearly full 1623
Clock Set To JT 1625
PC - Clock set to JT 1625
EVENT TYPES 12 = Disarm
Disarm System OP 1401
EVENT TYPES 13 = Engineer Access
Engineer Access LB 1627
Engineer Exit LX 1628
EVENT TYPES 14 = Door Access Alarm
Door Left Open DL 1426
Door Forced DF
EVENT TYPES 16 = Wrong Tag Used
Invalid Tag JA 1421
EVENT TYPES 17 = Special log input switcher opened
Input Special Log Switcher Input
Opened
UA 1146
EVENT TYPES 18 = Special log input switcher closed
Input Special Log Switcher Input
Closed
UR 3146
EVENT TYPES 19 = Special log input opened
Input Special Log Opened UA 1146
EVENT TYPES 20 = Special log input closed
Input Special Log Closed UR 3146
EVENT TYPES 21 = Sub Area Arm / Shunt Opened
Sub Area Armed CG 3402
Sub Area Input Armed CG 3402
Shunt Opened 3402
EVENT TYPES 22 = Sub Area Disarm / Shunt Closed
Sub Area Disarmed OG 1402
Sub Area Silenced OG 1402
Sub Area Input Disarmed OG 1402
Sub Area Input Silenced OG 1402
Shunt Closed 1402
EVENT TYPES 23 = Sub Area Alarm
Sub Area Alarm BA 1130
 