PCX 46 Programming Reference
Page: 42
9. Event Types
Description
SIA 3
Code
Contact ID
Code
Event Types
For CID

= Enabled,
Event Types
for SMS

= Disabled
EVENT TYPES 1 = Arm
Final Arm CL 3401
System Auto Armed CA 3403
System Rearm CP 3463
EVENT TYPES 2 = Auto Arm/Disarm
Forced Arm CF 3401
System Auto Disarmed OA 1403
Auto Arm cancelled by user CE 3405
EVENT TYPES 3 = Special Disarm
Special Disarm OP 1401
Access Exit Request DX 1425
EVENT TYPES 4 = Arm Error
Arm Fail CI 1454
EVENT TYPES 5 = Alarms
Fire Input Active FA 1110
Burglary Alarm BA 1130
Perimeter Alarm 1131
Interior Alarm BA 1132
Flood Active WA 1154
24h Alarm BA 1133
Entry Delay Alarm BA 1134
Tamper Alarm TA 1137
Expander Device Tamper TA 1137
Case Tamper TA 1137
Tamper on Sensor TA 1144
Gas Alarm GA 1151
Keybox Alarm 1250
Bell Tamper TA 1321
Radio Jamming XQ 1344
Radio supervision failure UY 1381
Radio low battery XT 1384
No Input Activity - sent NA 1680
EVENT TYPES 6 = Alarms send only once for one arm period
(This event type is suggested to be used with the SMS messages. We do not recommend enabling event type 5 and 6 in the
same time. One or another must be used to avoid double sending events)
Medical Alarm Send Once MA 1100
Fire Alarm Send Once FA 1110
PA Alarm Send Once PA 1120
Silent PA Alarm Input send Once HA 1122
Burglary Alarm Send Once BA 1130
Perimeter Alarm Send Once 1131
Interior Alarm Send Once BA 1132
24h Alarm Send Once BA 1133
Entry Delay Alarm Send Once BA 1134
Tamper Alarm Send Once TA 1137
Gas Alarm Send Once GA 1151
Keybox Alarm Send Once 1250
EVENT TYPES 7 = Alarms Silenced
Alarm Silenced OR 1406
EVENT TYPES 8 = Confirmed Alarm
Confirmed Output BV 1139
EVENT TYPES 9 = PSTN / GSM Line Fault Restore
CCTV Line fail (Line fail input) LT 1351
CCTV Line OK (Line fail input) LR 3351
Telecom Line OK (modem) LR 3351