After entering the setup mode on the remotes, use the following learn routine to
add remote controls to the system.
If the siren generates one long chirp when attempting to program the unit, the
learn routine is locked and must be unlocked using the Bitwriter® before pro-
ceeding.
The Valet/Program switch, plugged into the blue port, is used for programming.
There is a basic sequence to remember whenever programming this unit: Door,
Key, Choose, Transmit and Release.
1. Open a door. (The GREEN wire, H1/8, or the VIOLET,
H1/6 must be connected.
2. Insert the key. Turn the ignition to the ON position. The
heavy gauge pink wire must be connected.
3. Choose. Within 10 seconds, press and release the
Program switch corresponding to the number of the
desired function step listed in the following table.
Once you have selected the function step, press the switch once more and hold
it. The LED flashes and the siren chirps to confirm the selected functional step. Do
not release the Program switch.
Step Function
1
Auto Learn Standard Configuration* (default)
The auto learn configuration automatically sets up the remote's button con-
figuration.
Note: Due to the Supercode protocol, you cannot change the configuration.