EasyManuals Logo

Qlogic SANbox 5600 Series User Manual

Qlogic SANbox 5600 Series
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #279 background imageLoading...
Page #279 background image
A – Command Line Interface
Show Command
59097-02 B A-99
A
timezone
Displays the current time zone setting.
topology
Displays all connected devices.
users
Displays a list of logged-in users. This is equivalent to the User List command.
version
Displays an introductory set of information about operational attributes of the
switch. This keyword is equivalent to the About keyword.
PendingImageVersion - build date Firmware image version and build date
that is pending. This image will become
active at the next reset or power cycle.
ActiveConfiguration Name of the switch configuration that is in
use.
AdminState Switch administrative state
AdminModeActive Admin session status
BeaconOnStatus Beacon status as set by the Set Beacon
command.
OperationalState Switch operational state
PrincipalSwitchRole Principal switch status. True indicates that
this switch is the principal switch.
BoardTemp (1) - Degrees Celsius Internal switch temperature at circuit board
sensor 1
SwitchDiagnosticsStatus Results of the power-on self test
SwitchTemperatureStatus Switch temperature status: normal, warn-
ing, failure
Table A-28. Switch Operational Parameters (Continued)
Parameter Description

Table of Contents

Other manuals for Qlogic SANbox 5600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Qlogic SANbox 5600 Series and is the answer not in the manual?

Qlogic SANbox 5600 Series Specifications

General IconGeneral
BrandQlogic
ModelSANbox 5600 Series
CategorySwitch
LanguageEnglish

Related product manuals