5 – Diagnostics/Troubleshooting
Power-On Self Test Diagnostics
59265-00  A 5-9
A
5. Display the active zone set on each switch using the Zoning Active 
command, or click the Active Zoneset tab in QuickTools. Compare the zone 
membership between the two active zone sets. Are they the same?
 Yes - Contact your authorized maintenance provider.
 No - Deactivate one of the active zone sets or edit the conflicting zones 
so that their membership is the same, then reset the port. If the 
condition remains, contact your authorized maintenance provider.
Excessive Port Errors
The switch can monitor a set of port errors and generate alarms based on 
user-defined sample windows and thresholds. These port errors include the 
following:
 Cyclic Redundancy Check (CRC) errors
 Decode errors
 ISL connection count
 Device login errors
 Device logout errors
 Loss-of-signal errors
Port threshold alarm monitoring is disabled by default. Refer to the SANbox 
5802V Fibre Channel Switch Command Line Interface Guide for information about 
managing port threshold alarms.
If the count for any of these errors exceeds the rising trigger for three consecutive 
sample windows, the switch generates an alarm and disables the affected port, 
changing its operational state to down. Port errors can be caused by the following:
 Triggers are too low or the sample window is too small
 Faulty Fibre Channel port cable
 Faulty SFP
 Faulty port
 Faulty device or HBA
NOTE:
E_Port isolation can be caused by merging two fabrics whose 
active zone sets have two zones with the same name, but 
different membership.