EasyManua.ls Logo

Quantum StorNext M660 - Stornext M660 SAN Cabling

Quantum StorNext M660
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2: Hardware Overview
StorNext M660 Connectivity
42 StorNext M660 Metadata Appliance Hardware Guide
Table 9 StorNext M662
Network Configuration
StorNext M660 SAN
Cabling
Each StorNext M660 MDC node contains one 4-port 8Gb Fibre Channel
(FC) host bus adapter (HBA) card in PCIe expansion slot 3.
Note: If small form-factor pluggable (SFP) FC adapters are needed,
use only Intel-based SFP adapters. SFP adapters from other
vendors are not compatible with the FC HBA card used in the
StorNext M660. Twinax cables have the adapters built into the
end of the cable, so they do not require SFP adapters.
Fibre Channel Zoning
Each Fibre Channel port supports dual-port tape drives and libraries.
StorNext clients should not be zoned to access the tape drives/libraries
unless they are acting as a Distributed Data Mover host.
Ethernet
Port
Number
Logical
Ethernet
Port Number
Physical Port
Location
Port Function Bond
D N/A iDRAC Port
Service N/A
S eth0 Integrated Port 1
1 eth1 Integrated Port 2 GUI and Management
(Configurable from Service Menu)
Bond 1
When not bonded, eth1 is usable
and eth4 is not usable
2 eth2 Integrated Port 3
Metadata
(Configurable from
Service Menu)
When not bonded, eth2 is usable
and eth3 is not usable
3 eth3 Integrated Port 4 Bond 0
When not bonded, eth3 is not used
4 eth4 Slot 2, Port 1 GUI and Management
(Configurable from Service Menu)
Bond 1
When not bonded, eth4 is not used
5 eth5 Slot 2, Port 2
Gateway User Configurable from GUI
6 eth6 Slot 2, Port 3
7 eth7 Slot 2, Port 4
8 eth8 Slot 1, Port 1
(10 GbE)
9 eth9 Slot 1, Port 2
(10 GbE)