Figure 12: Reference Design for Debug UART Port
3.7.3. UART Application
The serial port voltage domain of this module is optional. Customers can select the appropriate voltage
domain through VIO_SEL according to actual situation. When VIO_SEL is floating, the VDD_EXT voltage
domain is 1.8 V; when VIO_SEL is grounded, the VDD_EXT voltage domain is 3.3 V or equals the VBAT
voltage
1)
.
If the voltage domain of your application system is 1.8 V, VIO_SEL can be floating; If the voltage domain
of your application system is 3.3 V, VIO_SEL must be grounded.
The following figure shows the reference design of UART:
Figure 13: Reference Design for UART
The following circuit shows a reference design for the communication between the module and a PC with
a standard RS-232 interface. Make sure to select appropriate voltage domain through VIO_SEL