LPWA Module Series
BG95&BG77&BG600L Series TCP/IP Application Note
BG95&BG77&BG600L_Series_TCP/IP_Application_Note 11 / 56
1.3. Description of Data Access Modes
The modules support three data access modes:
Buffer access mode
Direct push mode
Transparent transmission mode
When opening a socket service with AT+QIOPEN, you can specify the data access mode by
<access_mode>. After the socket service is opened, the data access mode can be changed with
AT+QISWTMD.
1. In buffer access mode, the module buffers data upon receiving it and reports a URC in the format of
+QIURC: "recv",<connectID>[,<data_len>] to notify the host of the incoming data. The host can
read the buffered data with AT+QIRD.
2. In direct push mode, the module outputs the received data directly through a URC in the format of
+QIURC: "recv",<connectID>,<currectrecvlength><CR><LF><data> or +QIURC: "recv",<con
nectID>,<currentrecvlength>,<remoteIP>,<remote_port><CR><LF><data>.
See Chapter 2.4.2 for more details.
3. In transparent transmission mode, the corresponding COM port (such as UART port, USB modem
port, etc.) enters exclusive mode, where data received from the port is sent to the Internet directly,
and data received from the Internet is outputted via the port directly.
Exit from transparent transmission mode
The module can exit from transparent transmission mode through either of the following ways.
1) Execute +++. Follow the requirements below to prevent the +++ from being misinterpreted as
data:
a) Do not input any character within 1 second before and after inputting +++.
b) Input +++ within 1 second, and wait until OK is returned. When OK is returned, the module
is switched to buffer access mode.
2) Change MAIN_DTR from LOW to HIGH to make the module enter command mode. In this case,
AT&D1 (see document [1]) should have been set before the module enters transparent
transmission mode.
Return to transparent transmission mode
1) By AT+QISWTMD. Specify <access_mode> as 2 when executing this command. When
transparent transmission mode is entered successfully, CONNECT is returned.
2) By ATO. After a connection exits from transparent transmission mode, executing ATO will switch

Table of Contents

Other manuals for Quectel BG95 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel BG95 Series and is the answer not in the manual?

Quectel BG95 Series Specifications

General IconGeneral
Form FactorLGA
Dimensions23.6 mm × 19.9 mm × 2.2 mm
Operating Temperature-40°C to +85°C
Storage Temperature-45°C to +90°C
GNSSGPS/GLONASS/BeiDou/Galileo/QZSS
SIM Interface1.8V/3.0V
LTE-FDD BandsB1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B26/B28
LTE-TDD BandsB39
Data rates LTE Cat NB2Uplink: 127 kbps, Downlink: 158.5 kbps
Data rates EGPRSUp to 296 kbps DL / 236.8 kbps UL
ProtocolsTCP/UDP/HTTP/HTTPS/MQTT/LWM2M/CoAP
InterfacesUART
CertificationsCE/FCC/PTCRB/IC/NCC/RCM/CCC