EasyManua.ls Logo

Quectel BG95 Series - PCM and I2 C Interfaces

Quectel BG95 Series
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LPWA Module Series
BG95&BG77&BG600L Series TCP/IP Application Note
BG95&BG77&BG600L_Series_TCP/IP_Application_Note 47 / 56
3.7.4. Switch Incoming Connection to Transparent Transmission Mode
3.7.5. Close a TCP Server
3.8. UDP Service under IPv4 Network
3.8.1. Start a UDP Service
OK
AT+QIRD=11,0 //Query the total length of received data, including read and unread data.
+QIRD: 4,4,0
OK
AT+QSWTMD=11,2 //Switch the incoming connection whose socket service
index is 11 to transparent transmission mode.
CONNECT
1234567890 //Send data directly.
+++ //Exit from transparent transmission mode.
OK
AT+QICLOSE=11 //Close the incoming connection. Depending on the
network, the maximum response time is 10 seconds.
OK
AT+QICLOSE=1 //Close TCP server listening.
OK
//Start a UDP service whose <connectID> is 2 and <context> is 1. Before using AT+QIOPEN, the host
should activate the context with AT+QIACT first.
AT+QIOPEN=1,2,"UDP SERVICE","127.0.0.1",0,3030,0
OK
+QIOPEN: 2,0 //UDP service is opened successfully.
AT+QISTATE=0,1 //Query the connection status of context 1.
+QISTATE: 2,"UDP SERVICE","10.7.157.1",0,3030,2,1,2,0,"usbmodem"
OK

Table of Contents