Section V - Preventive maintenance
24 Quincy Compressor
Notes:
1. Maintenance must be done according the number of running hours or according
the running period, whichever comes first.
2. Morefrequentlyinadustyenvironment.
3. Important note:Greasingofthebearingsofthecompressorelementmustbedone
with special grease, a special grease gun and according a specic procedure.
Inhighambientconditions,thebearingsmustbegreasedmorefrequently:for
every5°C(9°F)increaseabove30°C(86°F),themaintenanceintervalshouldbe
reducedwith30%.
Contact your supplier for details.
4. Inextremelydryconditions(relativehumiditybelow15%),thetipsealsanddust
sealsneedtobereplacedmorefrequently.
Service kits
Service kits
Foroverhaulingandforpreventivemaintenance,awiderangeofservicekitsisavailable.
Servicekitscompriseallpartsrequiredforservicingthecomponentandofferthe
benetsofgenuinepartswhilekeepingthemaintenancebudgetlow.
ConsulttheSparePartsListforpartnumbers.
Disposal of used material
Usedltersoranyotherusedmaterial(e.g.desiccant,lubricants,cleaningrags,machine
parts, etc.) must be disposed of in an environmentally friendly and safe manner, and in
line with the local recommendations and environmental legislation.
ElectroniccomponentsaresubjecttotheEUDirective2002/96/ECforWasteElectrical
andElectronicEquipment(WEEE).Assuch,thesepartsmustnotbedisposedofata
municipal waste collection point. Refer to local regulations for directions on how to
dispose of this product in an environmental friendly manner.