13
Operation
Measuring Resistance
1. Disconnect power from the circuit and discharge all capacitors.
2. Rotate the function dial to
Ω
.
3. Repeatedly press SELECT to select Ω, KΩ, or MΩ.
4. Connect the black test lead to one component lead.
5. Connect the red test lead to the other component lead, or remove one component lead
from its circuit and touch the test leads across the component.
nNote:
• Ifnoresistanceisconnectedacrossthetestleads(meaningresistanceisinnite),orthe
valueundertestingexceedstherangeyouset,O.F appears. This is normal.
• Ifyouaremeasuringresistanceofabout1MΩormore,thedisplaymighttakeafew
secondstostabilize.Thisisnormal.