Auto Power Off
Yourmeterconservespowerbyautomaticallyturningoffabout30minutesafterthelast
timeyouchangedasetting(evenifyouaretakingmeasurements).Themetershortbeeps
severaltimesandlongbeepsonceabout1minute,thenturnsoff.Pressanybuttonorselect
another function to turn it on.
To set the meter so that it does not turn off automatically, press and hold HOLD and
SELECT at the same time, as you turn on the meter. PLoc appears. When you release HOLD
and SELECT. PLoc disappears and
PWR
Lock
appears.
To reactivate the meter’s automatic power saving function, turn off the meter then turn it on.
PWR
Lock
disappears.
Testing the Display
To test the meter’s display, hold down any button while turning on the meter. All segments
appear on the display. Release the button to end the test.