To set a default tuning frequency:
1.  Press MAN. 
2.  (Optional) Use the number keys to enter the 
frequency number.
3.  Press FUNC, then TUNE. The scanner saves 
the frequency. For example, if you save 
145.31000 MHz, when you press TUNE, the 
scanner starts tuning at 145.31000 MHz.
Trunking Setup
Instead of transmitting on a specic frequency, 
trunking systems choose one of several 
frequencies during a 2-way radio transmission 
and simultaneously transmit a Talk Group ID 
that identies the 2-way radio user. This allows 
trunking systems to allocate fewer frequencies 
to multiple 2-way radio users. 
Dening a Trunking Bank
You can dene any of the 10 banks as a trunking 
bank, but each bank can only scan for one 
system: Motorola, EDACS (GE/Ericsson), or LTR 
(EF Johnson). 
Trunking banks can contain both trunking 
and non-trunking channels.
To dene a Trunking Bank:
1.  Press PGM, then press TRUNK to enter the 
ID program mode.
2.  Press FUNC, then use  or  to select a 
bank. 
3.  Repeatedly press MODE to select a trunking 
mode (Motorola, EDACS, or LTR).
4.  Press PGM.
Trunking Modes
In Closed mode, the scanner stops only on 
transmissions with saved and unlocked Talk 
Group IDs. This lets you focus a scan on the 
frequencies you have identied, ignoring other 
transmissions. 
In Open mode, the scanner stops for 
transmissions on any unlocked channel. This 
lets you search for Talk Group IDs that you can 
then save. 
While scanning, “–” appears for Closed mode 
and “+” appears for Open mode under 
the channel storage bank’s number. When 
the scanner stops on a channel,”OPEN” or 
“CLOSED” appears.
To set Open or Closed mode for a bank:
1.  Press MAN.
2.  Use  or  to select a bank.
3.  Press FUNC then DELAY. “Bank OPEN” or 
“Bank CLOSED” appears.
Motorola Trunking Setup
Motorola systems can allocate as few as ve 
frequencies to up to several thousand groups of 
users in three categories: 
•  Type I – User groups are assigned to eets. 
To scan, you must program a eet map into 
the scanner.
•  Type II – The Talk Group ID contains 4 or 5 
digit numbers.
•  Hybrid – Combines Type I and Type II 
formats.